Creating Oneview support dump file from the appliance maintenance console
This
procedure describes how to use the appliance maintenance console to create a
support dump file from the local appliancemodule (the appliance module on which
the appliance maintenance console runs) and store it on a USB drive.
If
the local appliance module is the active appliance module in an appliance
cluster and if the standby appliance module is reachable, the support dump will
contain the data for both cluster members. Otherwise, a support dump is created
with data for the local appliance module only.
The support dump file is encrypted by default.
Prerequisites•
Privileges: Infrastructure administrator
•Use a USB 2.0 or 3.0 device drive, formatted as an NTFS or
FAT32 file system and with only one partition. If necessary, use a computer to
format the USB drive.
The USB drive must have enough free space (typically 1 GB to
4 GB) to store the support dump file.
Procedure:
1. Install the USB drive in the USB port of the local
appliance module.
2. Access the appliance maintenance console main menu.
3. Select Support dump.A new set of commands appears.
4. Do one of the following:
•Select Create support dump to create a support dump file
and copy it to the USB drive.
•Select Download existing support dump to copy a support
dump file from the appliance module to the USB drive.
5. Wait until the support dump file is copied. The message
on the screen states that the support dump was successfully completed and that
it is safe to remove the USB drive.